+ iSCSI ( Internet Small Computer System Interface )
####################################################
- Completely separate protocol stack from Fibre channel
- Typically used in small to mid range SANs
- No dedicated SAN switches required which implies no SAN switching knowledge required
- 1/10 GigE iSCSI hardware offload cards available
- End host/Storage Array just runs IP
- Transport supports IP and can be of any IP Transport type like Ethernet, Frame Relay or Token Ring
- MDS is an iSCSI to FC Gateway, so MDS is a translational bridge for Fiber Channel & iSCSI
=====================================
+ iSCSI Gateway Operation
########################
- FC Targets FLOGI to FC Fabric
- iSCSI initiators send Discovery to MDS using Ethernet for example
- MDS applies zoning/Access Lists
- iSCSI initiator things FC target is iSCSI target
- FC Target thinks iSCSI initiator is a FC initiator
=====================================
+ MDS iSCSI Gateway Configuration Steps
#######################################
- Configure FC to Targets
- Configure IP to Initiators
- Enable iSCSI
- Configure ZONING/ Access Control
- Point Server at MDS's IP Address
=====================================
+ Access Control in iSCSI
##########################
- Access Control can be enforced as Zoning based upon :
> pwwn, fcid, alias
> Initiator's IP Address
> Initiator's iSCSI qualified name (IQN),IQNs are generated automatically by initiator
but can be configured manually.
> iSCI based virtual target to present LUN based on IQN or IP Address/Subnet
=====================================
sh int fc1/20 trunk vsan
feature iscsi
iscsi enable module 1
int iscsi 1/1
no sh
inc iscsi 1/2
no sh
iscsi import target fc
sh iscsi global
sh iscsi initiator
HTH...